Second & Third Series Solenoids


Second & Third Series  Solenoids

Magnete

Progress code Voltage Frequency Holding power In rush power Holding current Consumption In rush current Consumption Cosµ ED duty cycle Unipolar wires Bipolar wires Control: NC Control: NO
1a 12 V AC 50 HZ
60 HZ
2,95 VA
2,50 VA
5,5 VA
5,0 VA
245 mA
210 mA
460 mA
420 mA
0,61
0,60
100% F, C 300, 1000,
1450, 2000, 2500
1b 12 V DC 8,40 W 705 mA
100% F, C 300, 1000,
1450, 2000, 2500
2 12 V DC 5,62 W 475 mA 100% F, C 300, 1000,
1450, 2000, 2500
3 24 V AC 50 HZ
60 HZ
5,15 VA
4,45 VA
8,9 VA
8,0 VA
215 mA
185 mA
370 mA
335 mA
0,61
0,60
100% F, C 1000,
1450, 2000, 2500
4 24 V DC 6,40 W 265 mA
100% F, C 1000,
1450, 2500
5 L9V DC 3,7 W 400 mA Latching F, C 2500    
6 110 V AC 50 HZ
60 HZ
5,40 VA
4,55 VA
8,90 VA
8,15 VA
49 mA
41 mA
81 mA
74 mA
0,63
0,61
100% F, C 300, 620, 1000,
1450, 2500
7 230 V AC 50 HZ
60 HZ
6,45 VA
5,48 VA
9,60 VA
9,0 VA
28mA
24 mA
42 mA
39 mA
0,71
0,68
100% F, C 300, 620, 000,
1450, 2000, 2500