700 Series Solenoid


700 Series Solenoid

Magnete

Progressive code Voltage Frequency Holding power In Rush power Holding current In Rush current COS Duty Cycle Wires Unipolar Wires Bipolar Approvals Control NC Control NO
1a 12V AC 50 HZ
60 HZ
2,95 VA
2,50 VA
5,5 VA
5,0 VA
245 mA
210 mA
460 mA
420 mA
0,61
0,60
100% F, C
300, 1000, 1450, 2000, 2500 /
2b 12V DC = 8,40 W
/ 705 mA
/ / 100% F, C 300, 1000, 1450, 2000, 2500 /
2 12V DC = 5,65 WA
/ 475 mA
/ / 100% F, C 300, 1000, 1450, 2000, 2500 /
3 24V AC 50 HZ
60 HZ
5,15 VA
4,45VA
8,9 VA
8,0 VA
215 mA
185 mA
370 mA
335 mA
0,61
0,60
100% F, C 1000, 1450, 2000, 2500 /
4 24V DC = 6,40 W
/ 265 mA
/ / 100% F, C 1000, 1450, 2500 /
5 L9V DC = 5 W
/ 560 mA
/ / 100% F, C 2500 /    
6 110V AC 50 HZ
60 HZ
5,40 VA
4,55 VA
8,90 VA
8,15 VA
49 mA
41 mA
81 mA
74 mA
0,63
0,61
100% F, C 300, 620, 1000, 1450, 2500 /
7 230V AC 50 HZ
60 HZ
6,45 VA
5,48 VA
9,60 VA
9,00 VA
28 mA
24 mA
42 mA
39 mA
0,71
0,68
100% F, C 300, 620, 1000, 1450, 2000, 2500 /