Filter/check cartridge PPSU
-
Installation
-
Product can be installed in any positions
-
Applications
-
Where can be need a fluid filtration or a control of the fluid direction or both
-
Physical specifications
-
Body
PPSU
-
Gaskets:
LSR, FKM
-
Filter wire
AISI 304
-
Spring
AISI 316
-
Working specifications
-
Working pressure
0,05 - 10 bar
-
Room temperature
0÷120 °C (LSR), 0÷140 °C (FKM)
-
Fluid temperature
0÷120 °C (LSR), 0÷140 °C (FKM)
-
Fluid direction
Unidirectional
-
Orifice
DN3, DN4
-
Hydraulic connections
-
-
Inlet
Ø4mm Roemer quick connection
Ø6mm Roemer quick connection
-
Outlet
Ø4mm Roemer quick connection
Ø6mm Roemer quick connection
Technical data sheet
Model |
IN-OUT |
Orifice |
Filter |
Check valve |
Check + Filter |
F31649
|
Romer D, 4 mm
|
3 mm
|
|
|
|
F31669
|
Romer D, 6 mm
|
4 mm
|
|
|
|
F31649 7
|
Romer D, 4 mm
|
3 mm
|
|
|
|
F31669 7
|
Romer D, 6 mm
|
4 mm
|
|
|
|